Início
Quem Somos
Produtos
Baixar
Biblioteca Técnica
Contato
Interrogação
Mapa do Site
Ligações
 

Alarme & cabo Audio & Eletrônico

Belden Equivalente Cabos

Cabos coaxiais

Controle Cabos

Cabos de Fibra Óptica

Cabos Flexíveis

Instrumentação Cabos

Lan Cabos
Cabos de energia
Ferroviária Cabos

Robótica

Material Circulante Cabos
Rubber & Crane Cabos
Cabos de Segurança

Telefone Cabos

Aeroporto Cabos

Cabos Bus

Bucins

Data Cabos

Calor Detecção Cabos
High Temperature Cabos
Highway Cabos
Marine, Petróleo, Gás e Petroquímica Cabos
Cabos Especiais
Cabos espiraloidais
Termopar Cabos
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
 

Telefone Cabos

 PVC Insulated Jumper Wires to CW 1109, CW 1257 & CW 1423

Aplicativo

The jumper wires are used for interconnection between terminal blocks at main distribution frames (MDF), cross connection cabinets (CCP) and distribution frames or boxes.

Normas

• CW 1109 (PVC T2)

• CW 1257 (Cross linked PVC)

• CW 1423 (PVC BT M154)

Construção

Condutores
Solid annealed tinned copper 0.32/0.4/0.5/0.6/0.8/1.0mm as per class 1 of BS 6360/IEC 60228

Isolamento
PVC Type 2 to BS 6746 (CW 1109); Cross-linked PVC (CW 1257) & PVC (CW 1423)

Twisted Pairs
For CW 1109 & CW 1257, two insulated conductors are twisted into pairs with varying lays to minimize crosstalk. For CW 1423, one, two, three, four or five insulated conductors are twisted together with a right hand lay

Propriedades elétricas

CW 1109

Nominal Conductor Diameter

mm

0.32

0.4

0.5

0.6

0.8

1.0

7/0.2

Conductor Size

mm2

0.08

0.126

0.196

0.283

0.5

0.785

0.22

Maximum Conductor Resistance @20°C

Ω/km

234

148

95

65.9

36.7

23.3

89.9

Minimum Insulation Resistance @500V DC

MΩ.km

50

50

50

50

50

50

50

Minimum Insulation Thickness

mm

0.12

0.15

0.15

0.15

0.25

0.25

0.15

Maximum Insulated Conductor Diameter

mm

0.7

0.85

0.95

1.05

1.5

1.7

1.05

javascript:void(0)

CW 1257

Nominal Conductor Diameter

mm

0.4

0.5

0.6

Conductor Size

mm2

0.126

0.196

0.283

Maximum Conductor Resistance @20°C

Ω/km

153

98

68.9

Minimum Insulation Resistance @500V DC

MΩ.km

50

50

50

Minimum Insulation Thickness

mm

0.25

0.25

0.25

Maximum Insulated Conductor Diameter

mm

1.0

1.10

1.20

CW 1423

Nominal Conductor Diameter

mm

0.5

Conductor Size

mm2

0.196

Maximum Conductor Resistance @20°C

Ω/km

98

Minimum Insulation Resistance @500V DC

MΩ.km

50

Minimum Insulation Thickness

mm

0.25

Maximum Insulated Conductor Diameter

mm

1.10

Mechanical and Thermal Properties

Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 7.5 x Overall Diameter

Color Code

CW 1109 - as per IEC 60189-3
CW 1257 & CW 1423:

BLUE

ORANGE

GREEN

BROWN

GREY

WHITE

RED

BLACK

PINK

VIOLET

YELLOW

TURQUOISE

 

 

 

Dimensões e Peso

CW 1109

Cabo Código

Número de Fios

Espessura mínima de isolamento mm

Diâmetro máximo global
mm

Peso nominal kg/km

0.32mm Conductor, 0.7mm Insulated Wire

TP1109-Y-1W032

1

0.12

0.7

1.5

TP1109-Y-2W032

2

0.12

1.3

3.0

0.4mm Conductor, 0.85mm Insulated Wire

TP1109-Y-1W04

1

0.15

0.85

1.8

TP1109-Y-2W04

2

0.15

1.45

3.6

0.5mm Conductor, 0.95mm Insulated Wire

TP1109-Y-1W05

1

0.15

0.95

2.2

TP1109-Y-2W05

2

0.15

1.65

4.8

TP1109-Y-3W05

3

0.15

2.35

6.6

0.6mm Conductor, 1.05mm Insulated Wire

TP1109-Y-1W06

1

0.15

1.05

2.8

TP1109-Y-2W06

2

0.15

1.75

5.6

0.8mm Conductor, 1.5mm Insulated Wire

TP1109-Y-1W08

1

0.25

1.50

5.5

TP1109-Y-2W08

2

0.25

2.50

11.0

1.0mm Conductor, 1.7mm Insulated Wire

TP1109-Y-1W10

1

0.25

1.70

6.5

TP1109-Y-2W10 2 0.25 2.60 13.0
7/0.2mm Conductor, 1.05mm Insulated Wire
TP1109-Y-1W7/02 1 0.15 1.05

2.5

TP1109-Y-2W7/02 2 0.15 2.35

5.0

CW 1257

Cabo Código

Número de Fios

Minimum Insulation
Thickness mm

Maximum Overall
Diameter
mm

Peso nominal kg/km

0.4mm Conductor, 1.0mm Insulated Wire
TP1257-Y-1W04 1 0.25 1.0 2.0
TP1257-Y-2W04 2 0.25 1.8 4.0
0.5mm Conductor, 1.1mm Insulated Wire
TP1257-Y-1W05 1 0.25 1.1 2.5
TP1257-Y-2W05 2 0.25 2.0 5.0
0.6mm Conductor, 1.2mm Insulated Wire
TP1257-Y-1W06 1 0.25 1.2 2.9
TP1257-Y-2W06 2 0.25 2.2 5.8

CW 1423

Cabo Código

Número de Fios

Espessura mínima de isolamento mm

Diâmetro máximo global
mm

Peso nominal kg/km

0.5mm Conductor, 1.1mm Insulated Wire
TP1423-Y-1W05 1 0.25 1.98

2.5

TP1423-Y-2W05 2 0.25 2.5

5.0

TP1423-Y-3W05 3 0.25 3.0

7.5

TP1423-Y-4W05 4 0.25 3.8

10.0

TP1423-Y-5W05 5 0.25 4.6

12.5